UA-1000A 亮度&色度均匀性分析仪 TOPCON 拓普康
品牌:TOPCON 拓普康
The UA-1000A moves up measuring speed and functionality compared with current model UA-1000. The UA-1000A's measuring time is
Overview
The UA-1000A moves up measuring speed and functionality compared with current model UA-1000. The UA-1000A's measuring time is
Feature
- High speed mode is added (
About 5sec. at min for standard illuminant A) - Wide Dynamic range (0.005 - 100,000cd/m²)
- High resolution of 16bit(65,535 steps) make it possible to detect very slight difference in luminance and chromaticity.
- High resolution of 1.4 Mega pixel (Max 1360×1024 pixel)
- Standard application software can check and manage the uniformity and its data.
Specification
Photo detector | 1.4 million-pixel Monochrome Cooled CCD | ||
---|---|---|---|
Objective lens | Focal length 3-level switching system f=125mm (Wide angle) f=25mm (Standard) f=50mm (Telescopic) F2.8 |
||
Spectral sensitivity characteristic |
Approximate into the CIE 1931 color-matching function * This fulfills JIS Z 8724-1997 router condition. |
||
Number of measurement points |
1360x1024 (Binning1x1) 680x512 (Binning2x2) 340x256 (Binning4x4) |
||
Luminance measurement range |
0.005 to 100,000cd/m² | ||
Luminance linearity | ±3% ※standard sources A, Luminance 0.005 to 100,000cd/m², evaluated on the center of the CCD |
||
Chromaticity accuracy | ±0.005 ※standard sources A, Luminance 0.005 to 100,000cd/m², evaluated on the center of the CCD |
||
In-plane unevenness uniformity |
Luminance | ±2% | ※Center of the CCD, standard sources A, 30 cd/m² |
Chromaticity | ±0.003 | ||
Repeat Characteristic |
Luminance | 0.5% (2σ) | ※Standard Measurement Mode |
Chromaticity | 0.0020 (0.01cd/m² or more) 0.0025 (Less than 0.01cd/m²) |
||
Luminance | 0.65% (2σ, 0.1cd/m² or more) 0.75% (2σ, Less than 0.1cd/m²) |
※High-Speed Measurement Mode | |
Chromaticity | 0.0040 | ||
Measurement Time | Fastest (standard sources A, Binning 4x4, High-Speed Measurement Mode) |
||
Stability | Luminance | 1% (standard sources A, evaluated on the center of the CCD) | |
Repeatability | Luminance | 2% (standard sources A, evaluated on the center of the CCD) | |
Temperature characteristic |
Luminance | ±3% (At 15 to 30℃ ※reference: 25℃) | |
Humidity characteristic |
Luminance | ±3% (At 70%R.H.) | |
Calibration standard |
TOPCON calibration standard (standard sources A, 23℃±3℃) User calibration standard Switchable |
||
Interface | USB2.0 | ||
Power supply | 100 to 240V AC (50/60Hz) | ||
Power consumption | Photo detector: 100V, 120VA (Excluding the computer) |
||
Operating conditions | Temperature | 15℃ to 30℃ | |
Humidity | 70%R.H. and below (No condensation) | ||
Storage condition |
Temperature | -5℃ to 50℃ | |
Humidity | 70%R.H. and below (No condensation) | ||
Outer dimensions | 294(L)x210(W)x244(H)mm | ||
Weight | Only Detector: 6.9Kg With CloseupLens1: 9.6Kg With CloseupLens2: 10.6Kg |
Area
(It is possible to perform the following measurement depending on the display mode.)
Measurement distance (mm; metal, form) | |||||
---|---|---|---|---|---|
1000 | 1250 | 1500 | 1750 | 2000 | |
Wide angle (inch) |
30.5 | 37.6 | 44.6 | 51.6 | 58.6 |
Vertical(mm)/ Horizontal(mm) |
619.8/ 464.8 |
764.0/ 573.0 |
906.3/ 679.7 |
1048.5/ 786.4 |
1190.8/ 893.1 |
Standard (inch) |
16.5 | 20.0 | 23.6 | 27.1 | 30.6 |
Vertical(mm)/ Horizontal(mm) |
335.3/ 251.5 |
406.4/ 304.8 |
479.6/ 359.7 |
550.7/ 413.0 |
621.8/ 466.3 |
Telescopic (inch) |
9.4 | 11.2 | 12.9 | 14.7 | 16.4 |
Vertical(mm)/ Horizontal(mm) |
191.0/ 143.3 |
227.6/ 170.7 |
262.1/ 196.6 |
298.7/ 224.0 |
333.2/ 249.9 |
- *Measuring distance is from top of objective lens unit to object.
- *The value in this table are design reference values and may differ somewhat from the actual diameter.
AL-UA1 | AL-UA2 | |
---|---|---|
Measurement distance (mm; metal, form) |
553 | 78.1 |
Wide angle (inch) | 16.0 | 5.4 |
Vertical(mm)/Horizontal(mm) | 325.1/243.1 | 110.5/82.9 |
Standard (inch) | 8.0 | 2.7 |
Vertical(mm)/Horizontal(mm) | 162.6/121.9 | 55.3/41.5 |
Telescopic(inch) | 4.0 | 1.4 |
Vertical(mm)/Horizontal(mm) | 81.3/61.0 | 27.6/20.7 |
- *Measuring distance is from top of objective lens unit to object.
- *The value in this table are design reference values and may differ somewhat from the actual diameter.