| IMAGING PERFORMANCE | |
| Thermal: | |
| Detector type | ThermoVison2000: |
| Quantum Well Infrared Photodetector (QWIP): 320×240 pixels | |
| TermoVison3000: | |
| Quantum Well Infrared Photodetector (QWIP): 640×480 pixels | |
| Spectral range | 8.0 to 9.2μm |
| Number of fields of view | 3 |
| Field of view lens 1 | ThermoVision2000:25º (H) ×19 º (V) with 28 mm lens |
| ThermoVision3000:25º (H) ×19 º (V) with 37 mm lens | |
| Field of view lens 2 | ThermoVision2000:6º (H) ×4.5 º (V) with 116 mm lens |
| ThermoVision3000:7.8º (H) ×5.8 º (V) with 116 mm lens | |
| Field of view lens 3 | ThermoVision2000:0.99º (H) ×0.74 º (V) with 704 mm lens |
| ThermoVision3000:1.3º (H) ×0.96 º (V) with 704 mm lens | |
| Spatial resolution (IFOV) | ThermoVision2000:1.36 mrad for 28 mm lens |
| 0.33 mrad for 116mm lens -0.054 for 704 mm lens | |
| ThermoVision3000:0.68 mrad for 37 mm lens | |
| 0.22 mrad for 116 mm lens-0.036 mrad for 704 mm lens | |
| Thermal sensitivity | 30 mk max |
| Image frequency | ThermoVision2000: 50 Hz PAL or 60Hz NTSC |
| ThermoVision3000:25Hz PAL or 30 Hz NTSC | |
| Focus | Automatic or Manual |
| Electronic zoom | 2×,4× |
| Image processing | Digital Detail Enhancement (DDE):ThermoVision3000 only |
| Visual (Multisensor only): | |
| Built-in digital video | Sony FCB-EX-980S Color block camera (NTSC) |
| Sony FCB-EX-980SP Color block camera (PAL) | |
| Effective pixels | Approx.680,000 pixels NTSC- approx.800,000 pixels PAL |
| Low light option | Yes |
| Image stabilization | Yes |
| Optical zoom | 26×,42 º to 1.6 º continuous |
| Electronic zoom | 12×continuous |
| PAN-TILT:(Pan/Tilt versions only) | |
| Az Range; Az velocity | n×360 º;0.3 º-65 º/sec continuous |
| El Range; El velocity | +/-35 º;0.3 º-30 º /sec |
| Accuracy | 1 mrad |
| Resolution | 0.1 mrad |
| LASER RANGE FINDER (optional on multi-sensor) | |
| Type / range | Erbium glass, eye safe /80 m to 20 km |
| SYSTEM FEATURES | |
| Geo Positioning | Internal GPS: multi sensor only |
| Programmable search | Program multiple preset locations: Pan/Tilt version only |
| Remote Control | By serial link over TCP/IP |
| Automatic heater | Yes |
| Built-in Test(BIT) | Yes |
| Pelco D compliance | Yes |
| IMAGE PRESENTATION | |
| Video output | NTSC or PAL composite video, 14-bit digital image data |
| Connector types | BNC |
| VOIP | MPEG-2 or MPEG-4 video |
| POWER | |
| Requirements | 18-35 V DC |
| Consumption | 35 W typical-140 W with heaters |
| Multi-sensor:55 W typical-140 W with heaters | |
| ENVIRONMENTAL SPECIFICATIONS | |
| Operating temperature range | -32℃ to +55℃ |
| Storage temperature range | -40℃ to +70℃ |
| Automatic Window defrost | Yes |
| Humidity | Mil-Std-810F,506.4 |
| Sand/dust | Mil-Std-810F,510.4 |
| Icing/freezing rain | Mil-Std-810F,521.2 |
| Shock | Mil-Std-810F,516.5 |
| Vibration | Mil-Std-810F,514.4 |
| PHYSICAL CHARACTERISTICS | |
| Camera Weight | 18 kg-25 kg for multi sensor |
| Camera Size | 503×312×267 mm |
| Shipping size / weight | Sensor head: 440×630×580mm(h×w×l) 30 kg |
| Pan/Tilt:320×350×300 mm(h×w×l):14kg Pan/Tilt version only | |
| Accessories:440×630×580 mm(h×w×l) 25-30 kg | |
| (weight is depending on system cable length) | |
| INTERFACES | |
| TCP/IP | Command and control: all functions |
| RS-232 | Command and control: all functions |
| RS-485 | Command and control: all functions |
| STANDARD PACKAGES | ThermoVision2000/3000: |
| Thermal imaging camera, power supply, camera cable(7.5m), hand | |
| control, junction box, operator manual, shipping case | |
| ThermoVision2000/3000 Multi-sensor: | |
| Thermal imaging camera, daylight camera, Pan/Tilt, JPC(Junction and Protocol Converter) system, power | |
| supply with cables, system cable, Joy stick, junction | |
| box, operator manual, shipping cases(3). | |
| Optional: Laser Range Finder, Digital Magnetic Compass |